C&K systems System 238 Manuel d'installation Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
SYSTEM 238 Installation Manual
8
Command Locations 00 - 08
Command Location 00: Installer Combination
(1) (2) (3) (4) (5) (6)
012345
00
Default Values
Digit Position (1): First Digit of Installer Combination
0
Hard-coded to "0". Installer's combination will always start with 0.
Combination must have 5 digits in addition to Position (1).
Valid entries are 0 - 9.
Digit Positions (2) - (6): Remaining Digits in Combination
Command Location 01 - 08: User Arming Type and Combination
Digit Position (1): Arming Type
(1) (2) (3) (4) (5) (6)
91234E
10
1
**Default Values
01 = User #1 (Master)
02 = User #2
03 = User #3
04 = User #4
1 = Arm Only, No Closing (C) Report, No Shunting
2 = Disarm Only, No Opening (O) Report, No Shunting
3 = Arm and Disarm, No O/C Reports, No Shunting
05 = Us er # 5
0 6 = U s e r # 6
0 7 = U s e r # 7
08 = User #8 (Guest)
4 = Arm Only, with Closing Report, No Shunting
5 = Disarm Only, with Opening Report, No Shunting
6 = Arm and Disarm, with O/C Reports, No Shunting
7 = Arm Only, No Closing Report, Shunting Allowed
8 = Disarm Only, No Opening Report, Shunting Allowed
9 = Arm and Disarm, No O/C Reports, Shunting Allowed
0 = Arm Only, with Closing Report, Shunting Allowed
1 = Disarm Only, with Opening Report, Shunting Allowed
2 = Arm and Disarm, with O/C Reports, Shunting Allowed
Digit Position (2): First Digit of Arming Code
Hard-coded to User's PIN. You cannot change this number.
Digit Positions (3) - (6): Remaining Digits in Combination
Comination may have from 1 - 4 digits in addition to Position (2).
Valid entries are 0 - 9.
**Default Values are different for
each user. Refer to the SYSTEM
238 Programming Worksheet at the
end of this manual for other user
default values.
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
NOTE: Some programming locations allow variable-length data and require an
End-of-Number (EON) character. Program 4 ("E") after the last digit.
Fill remaining unused Positions with "0". The EON character is not required
if the last digit is in Position (6).
Vue de la page 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 27 28

Commentaires sur ces manuels

Pas de commentaire