CK-LENS KIT
Universal lens kit.
Contains 1 pet-alley lens and 1 curtain lens.
Used for the XJ-450T and MC-550T.
CK-LENS XJLR
Long range curtain lens – 30.5 m.
Used for the XJ-450T.
CK-LENS KIT 17
Contains 1 pet-alley lens and 1 curtain lens.
Used for the DT-700 or DT-706.
CK-LENS KIT 18
3 m Mounting height lens.
Used for the MC-760T.
CK-LENS KIT 19
Curtain lens for the MC-760T.
CK-LENS KIT 20
Pet-alley lens for the MC-760T.
F
LEX
G
UARD
®
G
LASSBREAK
D
ETECTORS
FLEXGUARD
®
FlexGuard glassbreak detectors are based on a technology that
detects a glassbreak event by listening for the acoustical data
generated when glass is broken.
When glass breaks, it produces two distinct sounds:
1. The flex; a low frequency sound generated by a blow to the glass.
2. The audio; a high frequency sound generated by the breaking glass.
FlexGuard detectors use dual channel technology for improved false
alarm immunity. An alarm is generated only when a low frequency
‘flex’ signal is followed within a 200 ms time-window by a high
frequency ‘audio’ signal. Both signals must have valid amplitude,
duration and frequency characteristics.
CK-FG730
Range : 9 m
Voltage : 10 ~ 14 Vdc
Current : 25 mA @ 12 Vdc
Operating temperature : -20ºC ~ 55ºC
(UL 0ºC ~ 49ºC)
Application : residential and
light commercial
applications
CK-FG1008 /1015/1025/1025R
Based on the extended flex/audio principle of dual technology
sensing, but with far more signal processing using an on board
microcontroller. The FG-1000 series glassbreak detectors apply
Digital Signal Processing using an on board microcontroller to
instantly digitise sounds into mathematic sequences, distinguishing
common false alarms from breaking glass. The advantage of Digital
Signal Processing (DSP) makes these unique ‘intelligent’ detectors
more computer than detector.
CK-FG1008
Range : 2.4 m maximum
Voltage : 8 ~ 14 Vdc
Current : 17 mA @ 12 Vdc
Operating temperature : 0ºC ~ 49ºC
Features : includes both a
glassbreak
detector and a
magnetic contact
Application : glass doors;
sliding doors
CK-FG1025
Range : 7.6 m
Voltage : 8 ~ 14 Vdc
Current : 25 mA @ 12 Vdc
Operating temperature : 0°C ~ 49ºC
Application : residential and
industrial