CIRCUIT PROGRAMMING 4 (Range 2-7)
Circuits 2 - 7 can be reprogrammed to suit your requirements. Circuit 1 is
fixed as a Final exit circuit. Circuit 8 has limited options.
ENTER PROGRAM ZONE ENTER PROGRAM ZONE
4 - 2 2 4 - 6 6
4 - 3 3 4 - 7 7
4 - 4 4 4 - 8 8
4 - 5 5
Select the circuit you wish to alter, it may then be programmed by entering one
key from the following table.
N/S = Night Set
Option no. Zones 2-7 Zone 8
1 Alarm Alarm
2 Alarm with walk through Fire
3 Alarm & Isolate in Night Set PA
4 Alarm, Walk through & Isolate in N/S Keyswitch
5 Alarm, Walk through & N/S Entry
6 Fire
7 Entry Route
8 P.A
SEE GLOSSARY OF TERMS (p.11) FOR DESCRIPTIONS OF ZONE TYPES etc.
To program zone 3 as an “Entry Route” enter - 4 3 7 *
To program zone 8 as a “Keyswitch” enter - 4 8 4 *
Momentary keyswitch Turn and hold for 0.5 sec = FULL SET
Turn and hold for 2.3 sec = PART SET
EXTENDED PROGRAMMING OPTIONS 7 (Range 1-8)
Enter 7 - 1 Disables sounder & strobe in night set.
Enter 7 - 2 Keypress tamper alarm (after 16 incorrect keypresses)
Enter 7 - 3 Full set door sense setting.
Enter 7 - 4 Convert L+ to ID- output.
Enter 7 - 5 Allow Manual Isolation of Zone 1 (Entry/Exit) In Night Set.
Enter 7 - 6 Remote Keypad PA Enable (Operated by * & # ).
Enter 7 - 7 L+ signals first to alarm.
Enter 7 - 8 Inhibit strobe in Night and Home Set and testing. (For
speech dialler connection)
HOME SET ZONE SELECTION 8 (Range 1-8 N/A if Fire or PA)
The Home Set feature enables parts of the premises to be alarm protected
while other parts are occupied. This is similar to Night Set except that an
Exit/Entry route is not required as part of the Setting or Unsetting procedure.
In programming mode press 8 to select Home Set zone selection mode, then
by pressing the keys 1-8 on the keypad you will select which zones you want
ISOLATED during home set. As a key is pressed, its relevant LED on the
display will toggle on or off. Any LED’s that are ON will be ISOLATED during
home set and any that are off will remain ACTIVE.
CIRCUIT
PROGRAMMING
ZONE
SELECTIONS
EXTENDED
PROGRAMMING
HOME SET
ZONE