20
Command Location 24: Shunting Enable
24
111111
(1) (2) (3) (4) (5) (6)
Default Values
#
Digit Position (1): Loop 1 Shunting Enable
0 = No: makes this zone a priority zone (not shuntable)
1 = Yes: authorized users can bypass or force arm
Digit Position (2): Loop 2 Shunting Enable
Refer to Digit Position (1) for programming options.
Digit Position (3): Loop 3 Shunting Enable
Refer to Digit Position (1) for programming options.
Digit Position (4): Loop 4 Shunting Enable
Refer to Digit Position (1) for programming options.
Digit Position (5): Loop 5 Shunting Enable
Refer to Digit Position (1) for programming options.
Digit Position (6): Loop 6 Shunting Enable
Refer to Digit Position (1) for programming options.
Command Location 25: Delay Before Dial Enable
25
000000
(1) (2) (3) (4) (5) (6)
Default Values
#
Digit Position (1): Loop 1 Delay Before Dial Enable
0 = No
1 = Yes: this loop will delay dialing on alarm for time programmed in CL 1B (4)
Digit Position (2): Loop 2 Delay Before Dial Enable
Refer to Digit Position (1) for programming options.
Digit Position (3): Loop 3 Delay Before Dial Enable
Refer to Digit Position (1) for programming options.
Digit Position (4): Loop 4 Delay Before Dial Enable
Refer to Digit Position (1) for programming options.
Digit Position (5): Loop 5 Delay Before Dial Enable
Refer to Digit Position (1) for programming options.
Digit Position (6): Loop 6 Delay Before Dial Enable
Refer to Digit Position (1) for programming options.
Command Location A0: Test Report Countdown Timer
(1)
A0
#
Digit Position (1): Set Test Report Countdown Timer
This command sets the time when the first Test Report is transmitted to the central station. The SYSTEM 236 will
use this transmission time whenever it is powered up or the CPU is reset
(unless CL A0 is reprogrammed).
Example:
The time is 1500 hours (3:00 pm). You want the first Test Report to
transmit at 0100 hours (1:00 am). 3:00 pm + 10 hours = 1:00 am.
Program the value "8" in Position (1) of CL A0.
0 = 1/4 hour
1 = 1/2 hour
2 = 1 hour
3 = 2 hours
4 = 3 hours
5 = 4 hours
6 = 6 hours
7 = 8 hours
8 = 10 hours
9 = 24 hours
0 = 14 hours
1 = 16 hours
2 = 18 hours
3 = 20 hours
4 = 22 hours
5 = 24 hours
CL 24 - 25 and A0